Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
OBJECTIVE To compare the rates of hormonal evaluation in patients who had CT reports describing adrenal incidentalomas with and without a specific recommendation for hormonal evaluation. MATERIALS AND METHODS We performed a retrospective review of adult outpatients without a history of cancer who had a CT report describing an incidental adrenal nodule. Radiology reports were reviewed to determine whether a standardized macro was used which gave specific recommendations for hormonal evaluation and endocrinology consultation. If no macro was used it was determined whether the report had a recommendation for hormonal evaluation and endocrinology consultation. RESULTS A standardized macro recommending hormonal evaluation and endocrinology referral was used in 45/129 (34.8%) reports that described an incidental adrenal nodule. A recommendation for hormonal evaluation was made in 5/84 (6.0%) reports without a macro. Hormonal evaluation was performed in 24/50 (48.0%) patients whose reports recommended it and in 11/79 (13.9%) patients whose reports did not (p less then 0.0001). A recommendation for endocrinology referral was made in 2/84 (2.4%) reports without a macro. Patients were seen by endocrinology in 12/47 (25.5%) patients whose reports recommended an endocrinology referral evaluation and 5/82 (6.1%) patients whose reports did not (p less then 0.0001). Hormonal evaluation was performed in 17/17 (100%) patients who were seen by endocrinology and 18/112 (16.1%) patients who were not (p less then 0.0001). Eleven patients (8.5%) had an evaluation suggesting hyperfunctioning nodules (4 cortisol producing, 6 aldosterone producing, and 1 pheochromocytoma). CONCLUSIONS Utilizing standardized macros that make specific recommendations for hormonal evaluation in patients with adrenal incidentalomas leads to improved adherence to clinical guidelines.PURPOSE To establish measurement quality criteria for the noninvasive assessment of clinically significant portal hypertension (CSPH) in patients with cirrhosis using CT-based liver surface nodularity (LSN) measurements. METHODS Seventy-four consecutive patients with cirrhosis (mean 62 ± 13 years), including 30 with CSPH (41%), underwent CT and hepatic venous pressure gradient measurements. Three independent readers performed 15 LSN measurements/patient using dedicated software. LSN was computed based on the median and means of one to 15 measurements. Accuracy for diagnosing CSPH was assessed using receiver operating characteristic (ROC) curve analysis. Variability was assessed by the intra-class correlation coefficient (ICC) and the Bland-Altman plot (BA). Quality criteria were identified to maximize the accuracy of LSN and minimize variability. RESULTS The area under the (AU) ROCs of mean and median LSN measurements based on one to 15 measurements ranged from 0.79 ± 0.05 to 0.91 ± 0.04 and 0.86 ± 0.04 to 0.91 ± 0.03, respectively, with no difference on pair-wise comparisons (all p > 0.05). AUROCs of LSN increased from one to eight and leveled off between eight and 15 measurements. Inter- and intra-reader variability decreased from one to 15 measurements, with only slight improvement after more than eight measurements. Intra- and inter-observer agreements were excellent with eight measurements (ICC = 0.90 [95%CI 0.84-0.94], and ICC = 0.93 [95%CI 0.89-0.95], respectively), and variability for intra-observer and inter-observer agreement was low (BA bias 4.2% (95% limits of agreement [LoA] [- 15.3; + 23.7%]) and 4.8% LoA [ - 17.5; + 27.1%], respectively). CONCLUSIONS CT-based LSN measurement is highly reproducible and accurate. We suggest using at least 8 valid measurements to determine the mean LSN value for the detection of CSPH.The role of the radiologist in the diagnosis and management of patients with endometriosis is increasing. Improvement in MRI imaging techniques has improved detection rate of subtle manifestations of endometriosis by radiologists. Therefore, the role of imaging in the diagnosis and follow-up after treatment is also likely to increase. Knowledge of new medical management pathways used in treating patients with endometriosis-related pain is important. The knowledge of various medication regimens will allow radiologists to continue to evaluate baseline disease, and to potentially assess for imaging response/stability to these medications. This article will review the current medical therapies in use in the management of endometriosis-related pain and describe potential imaging-related findings expected with these therapies.PURPOSE Metastatic gastroenteropancreatic neuroendocrine neoplasms (mGEP-NEN) are indolent malignancies which undergo frequent imaging follow-up. Hepatocellular phase (HCP) MR with hepatocellular-specific contrast agent is widely used to evaluate mGEP-NEN liver metastases but is commonly performed after a 20-min delay which prolongs scan time. The purpose of this study was to evaluate if HCP MR at 15 min offers comparable performance to 20-min delay for patients with mGEP-NEN undergoing routine imaging surveillance. MATERIALS AND METHODS In this IRB-approved retrospective study, we evaluated 52 patients with mGEP-NEN who were imaged for routine surveillance with gadoxetate disodium (Eovist®)-enhanced MR including 15- and 20-min delayed HCP. Two readers (R1, R2), blinded to HCP timing, independently reviewed each set of images in random order at least 1 month apart. Readers assessed presence and conspicuity of metastases, and subjective image quality using 5-point scales. Readers quantified the number of metastases and diameter of the largest lesion. Statistical analysis was performed to determine individual-reader and inter-reader differences for qualitative and quantitative data. RESULTS No differences were observed for subjective image quality (R1 p = 0.86, R2 p = 0.17) or lesion conspicuity (R1 p = 0.56, R2 p = 0.74) at 15 min and 20 min for either reader. https://www.selleckchem.com/ Individual-reader concordance correlation coefficient between 15 and 20 min was high for number of metastases detected (R1 = 0.9842, R2 = 0.9579) and diameter of largest metastasis (R1 = 0.9629, R2 = 0.8859). CONCLUSION HCP imaging at 15 min provides similar diagnostic yield to standard 20-min delay, which may help reduce the scan time and costs, and improve throughput and patient satisfaction.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत