Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
[This corrects the article PMC7566692.].For finite-dimensional problems, stochastic approximation methods have long been used to solve stochastic optimization problems. Their application to infinite-dimensional problems is less understood, particularly for nonconvex objectives. This paper presents convergence results for the stochastic proximal gradient method applied to Hilbert spaces, motivated by optimization problems with partial differential equation (PDE) constraints with random inputs and coefficients. We study stochastic algorithms for nonconvex and nonsmooth problems, where the nonsmooth part is convex and the nonconvex part is the expectation, which is assumed to have a Lipschitz continuous gradient. The optimization variable is an element of a Hilbert space. We show almost sure convergence of strong limit points of the random sequence generated by the algorithm to stationary points. We demonstrate the stochastic proximal gradient algorithm on a tracking-type functional with a L 1 -penalty term constrained by a semilinear PDE and box constraints, where input terms and coefficients are subject to uncertainty. We verify conditions for ensuring convergence of the algorithm and show a simulation.Digital subtraction angiography (DSA) is the main imaging modality used to assess reperfusion during mechanical thrombectomy (MT) when treating large vessel occlusion (LVO) ischemic strokes. To improve this visual and subjective assessment, hybrid models combining angiographic parametric imaging (API) with deep learning tools have been proposed. These models use convolutional neural networks (CNN) with single view individual API maps, thus restricting use of complementary information from multiple views and maps resulting in loss of relevant clinical information. This study investigates use of ensemble networks to combine hemodynamic information from multiple bi-plane API maps to assess level of reperfusion. Three-hundred-eighty-three anteroposterior (AP) and lateral view DSAs were retrospectively collected from patients who underwent MTs of anterior circulation LVOs. API peak height (PH) and area under time density curve (AUC) maps were generated. CNNs were developed to classify maps as adequate/inadequate reperfusion as labeled by two neuro-interventionalists. Outputs from individual networks were combined by weighting each output, using a grid search algorithm. Ensembled, AP-AUC, AP-PH, lateral-AUC, and lateral-PH networks achieved accuracies of 83.0% (95% confidence-interval 81.2%-84.8%), 74.4% (72.0%-76.7%), 74.2% (72.8%-75.7%), 74.9% (72.2%-77.7%), and 76.9% (74.4%-79.5%); area under receiver operating characteristic curves of 0.86 (0.84-0.88), 0.81 (0.79-0.83), 0.83 (0.81-0.84), 0.82 (0.8-0.84), and 0.84 (0.82-0.87); and Matthews correlation coefficients of 0.66 (0.63-0.70), 0.48 (0.43-0.53), 0.49 (0.46-0.52), 0.51 (0.45-0.56), and 0.54 (0.49-0.59) respectively. Ensembled network performance was significantly better than individual networks (McNemar's p-value less then 0.05). https://www.selleckchem.com/products/icec0942-hydrochloride.html This study proved feasibility of using ensemble networks to combine hemodynamic information from multiple bi-plane API maps to assess level of reperfusion during MTs. Computed tomography perfusion (CTP) is used to diagnose ischemic strokes through contralateral hemisphere comparisons of various perfusion parameters. Various perfusion parameter thresholds have been utilized to segment infarct tissue due to differences in CTP software and patient baseline hemodynamics. This study utilized a convolutional neural network (CNN) to eliminate the need for non-universal parameter thresholds to segment infarct tissue. CTP data from 63 ischemic stroke patients was retrospectively collected and perfusion parameter maps were generated using Vitrea CTP software. Infarct ground truth labels were segmented from diffusion-weighted imaging (DWI) and CTP and DWI volumes were registered. A U-net based CNN was trained and tested five separate times using each CTP parameter (cerebral blood flow (CBF), cerebral blood volume (CBV), time-to-peak (TTP), mean-transit-time (MTT), delay time). 8,352 infarct slices were utilized with a 603010 trainingtestingvalidation split and Monte Carlo cross-validation was conducted using 20 iterations. Infarct volumes were reconstructed following segmentation from each CTP slice. Infarct spatial and volumetric agreement was compared between each CTP parameter and DWI. Spatial agreement metrics (Dice coefficient, positive predictive value) for each CTP parameter in predicting infarct volumes are CBF=(0.67, 0.76), CBV=(0.44, 0.62), TTP=(0.60, 0.67), MTT=(0.58, 0.62), delay time=(0.57, 0.60). 95% confidence intervals for volume differences with DWI infarct are CBF=14.3±11.5 mL, CBV=29.6±21.2 mL, TTP=7.7±15.2 mL, MTT=-10.7±18.6 mL, delay time=-5.7±23.6 mL. CBF is the most accurate CTP parameter in segmenting infarct tissue. Segmentation of infarct using a CNN has the potential to eliminate non-universal CTP contralateral hemisphere comparison thresholds. CBF is the most accurate CTP parameter in segmenting infarct tissue. Segmentation of infarct using a CNN has the potential to eliminate non-universal CTP contralateral hemisphere comparison thresholds.X-ray guided neurointerventions are catheter-based treatments for cerebrovascular diseases such as strokes and aneurysms. During such procedures visualization of treatment devices is the primary imaging task. In this work we investigate the necessity of x-ray scatter-reduction grids in performing those tasks. Various endovascular treatment devices such as stents, coils and catheters along with a low contrast blood vessel phantom were placed on a head-equivalent phantom. Images of the objects were acquired with and without a grid (151 grid ratio, 80 lines/cm and Al interspace). The x-ray field was set to the full 8 x 8 inch FOV to allow for realistic scatter generation. The detector was positioned close to the phantom to investigate maximal scatter conditions. Contrast and Contrast to Noise (CNR) ratios of the catheter tip and the blood vessel phantom were measured and compared for images obtained with and without the grid. The x-ray technique parameters were kept constant for all acquisitions. For the catheter tip there was a 43% reduction in contrast with the removal of the grid due to increased scatter reaching the detector.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत