Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
The tablet-based screening system had a positive impact on clinician workflows and the overall effectiveness of clinic operations. This system supports providers in addressing the behavioral health needs of patients that often go unrecognized in primary care.It is clear that interdisciplinary communication and collaboration have the potential to mitigate healthcare-associated harm, yet there is limited research on how communication through documentation in the patient record can support collaborative decision making. Understanding what information is needed to support collaborative decision making is necessary to design electronic health information systems that facilitate effective communication and, ultimately, safe care. To explore this issue, we focused on information needs related to central venous catheter management and the prevention of central line-associated blood stream infections. https://www.selleckchem.com/products/itacnosertib.html Semistructured interviews were conducted with nurses working in an intensive care unit. Interview transcripts were analyzed using inductive thematic analysis. Three themes were identified (1) challenges managing documentation in multiple places in the absence of formal documentation processes for central venous catheter management; (2) lack of standardized decision-making processes for managing central venous catheters; and (3) oral communication holds it together. Our findings provide a foundation for the development of EHR functional requirements that enhance communication regarding the management of central venous catheters and facilitate the prompt removal of unnecessary lines. In complex regional pain syndrome (CRPS), sensory deficits and/or hyperalgesia often extend beyond the affected limb to encompass other sites on the ipsilateral side of the body. The aim of this study was to determine whether hyperalgesia in the ipsilateral forehead reflects disinhibition and/or sensitization of trigeminal afferent or second-order neurons on the CRPS-affected side. To investigate this, blink reflexes to supraorbital electrical stimuli (a 2 mA triple pulse delivered using a concentric electrode) were recorded bilaterally in 30 CRPS patients and 20 controls of similar age and sex distribution. In addition, the effect of acoustic startle stimuli on pain and blink reflexes to supraorbital electrical stimuli was explored. Supraorbital electrical stimulation was more painful on the affected than unaffected side in patients (P<0.05), and was more painful on both sides in patients than controls (P<0.001). In addition, electrical stimulation of the ipsilateral forehead increased loudness aystem may generate hyperacusis in CRPS.The multistep process of oral carcinogenesis provides a biological rationale for the use of chemoprevention in individuals at increased risk of developing oral cancer. We aimed to determine if low doses of propranolol can prevent the development of oral cancer using a tobacco-relevant and p53-associated animal model of cancer initiation. Twenty-six Wistar rats were randomly allocated into two groups, vehicle, and propranolol. All animals received 4-nitroquinoline N-oxide (4NQO) at 25 ppm diluted in the drinking water for 20 weeks. Animals from the propranolol group received propranolol (0.1 mg/kg) 5 days per week by gavage for 18 weeks. The clinical analysis was performed by measuring the area of the lesion and assessment of scores based on lesion appearance (papule; plaque; nodule or ulcerated). Histopathological analysis was performed to determine the presence of epithelial dysplasia or invasive squamous cell carcinoma (SCC). The average lesion area in 4NQO + vehicle and in 4NQO + propranolol groups were 0.20 and 0.28 mm, respectively (P = 0.53). The percentage of cases clinically graded as papules, thick plaques, nodular areas, and ulcerated lesions was similar between groups (P = 0.94). Histopathological diagnosis also did not differ between groups (P = 0.65), with 54.5 and 70% of cases being diagnosed as SCC in 4NQO and in 4NQO + propranolol groups, respectively. In conclusion, daily doses propranolol at 0.1 mg/kg were not as effective as a chemopreventive therapy in an animal model of 4NQO-induced carcinogenesis.We report a case of a 55-year-old man who presented with recurrent syncope 15 months after HeartWare left ventricular assist device (LVAD) implantation and was found to have diminished LVAD flow and pulsatility on tilt table testing leading to severe orthostatic hypotension (OH). The prevalence of OH is common, but autonomic dysfunction leading to OH has not been well described in patients with chronic LVAD support. The diagnosis of OH in this setting is challenging due to the decreased pulsatility in the flow generated by LVADs, and tilt table testing can be useful in the evaluation of OH in these patients.Extracorporeal circulation (ECC) support using intraoperative extracorporeal membrane oxygenation (ECMO) during lung transplantation (LTx) is now a routine practice for many high volume centers. Circuits that are dedicated to ECMO alone can be expensive and do not allow full cardiopulmonary bypass (CPB) to be performed. We describe our technique of instituting venoarterial ECMO during LTx using a less-expensive hybrid circuit that facilitates easy and immediate conversion to full CPB if needed, without interruption of ECC.Extracorporeal CO2 removal (ECCO2R) can permit lung protective or noninvasive ventilation strategies in patients with chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). With evidence supporting ECCO2R growing, investigating factors which affect CO2 removal is necessary. Multiple factors are known to affect the CO2 removal rate (vCO2) which can complicate the interpretation of changes in vCO2; however, the effect of hematocrit on the vCO2 of artificial lungs has not been investigated. This in vitro study evaluates the relationship between hematocrit level and vCO2 within an ECCO2R device. In vitro gas transfer was measured in bovine blood in accordance with the ISO 7199 standard. Plasma and saline were used to hemodilute the blood to hematocrits between 33% and 8%. The vCO2 significantly decreased as the blood was hemodiluted with saline and plasma by 42% and 32%, respectively, between a hematocrit of 33% and 8%. The hemodilution method did not significantly affect the vCO2.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत