Respiratory support of the critically ill neonate has steadily shifted from invasive to noninvasive forms of support. There have recently been a number of important advances in our understanding of the changes to neonatal resuscitation practices as they pertain to clinically important outcomes, mechanisms of gas exchange for high-flow nasal cannula, and best use of noninvasive ventilation and predicting response. Although the proportion of infants requiring intubation and mechanical ventilation has decreased, the most severely ill often still require intubation and ventilation. Recently, volume-targeted ventilation, high-frequency ventilation, and different methods of assessing weaning and extubation have been investigated. This review summarizes a number of important advances that have been made in the management of prematurity and neonatal respiratory distress syndrome. Copyright © 2020 by Daedalus Enterprises.BACKGROUND The benefits of inspiratory muscle training (IMT) for patients with COPD are documented in the literature, but its isolated effect or association with other interventions, the best training methods, and what type of patient benefits the most are not clear. We sought to assess the effects of IMT on respiratory muscle strength, pulmonary function, dyspnea, functional capacity, and quality of life for subjects with COPD, considering IMT isolated or association with other interventions, presence of inspiratory muscle weakness, training load, and intervention time. METHODS We searched the MEDLINE, EMBASE, PEDro, Cochrane CENTRAL, and LILACS databases in June 2018. We also performed a manual search of references in the studies found in the database search and included in this analysis. We included randomized controlled trials that investigated the above-mentioned outcomes and assessed IMT, either isolated or associated with other interventions, in comparison with a control group, placebo, or other intervlity of life. https://www.selleckchem.com/PI3K.html Associated IMT only increased inspiratory muscle strength. These results indicate that isolated IMT can be considered as an adjuvant intervention in patients with COPD. Copyright © 2020 by Daedalus Enterprises.BACKGROUND The guidelines to conduct and interpret conventional pulmonary function (PFT) tests are frequently reviewed and updated. However, the quality assurance and quality control (QA/QC) guidelines for respiratory oscillometry testing remain limited. QA/QC guidelines are essential for oscillometry to be used as a diagnostic pulmonary function test (PFT) in a clinical setting. METHODS We developed a QA/QC protocol shortly after oscillometry was introduced in our laboratory as part of a clinical study. The first clinical study began after the research personnel completed 3 h of combined didactic and hands-on training and establishment of a standard operating protocol (SOP) for oscillometry testing. All oscillometry tests were conducted using the initial SOP protocol from October 17, 2017, to April 6, 2018. At this time, the first QA/QC audit took place, followed by revisions to the SOP, the addition of a QA/QC checklist, and the development of a 12-h training program. A second audit of oscillometry tests waht © 2020 by Daedalus Enterprises.BACKGROUND Infant respiratory distress remains a significant problem worldwide, leading to more than one million neonatal deaths each year. The cost, maintenance, energy, and personnel required to implement ventilators have proven to be a barrier in many resource-limited settings. To address these barriers, a nonelectric bubble noninvasive positive pressure ventilation (NIV) device was developed. This study aims to benchmark the performance of this bubble NIV device against commercially available ventilators. METHODS The delivered pressure waveforms and tidal volumes of the bubble NIV device were compared with those of 2 conventional ventilators (ie, Dräger Evita Infinity V500 and Hamilton G5) at the following pressure settings 8/5, 12/5, and 15/5 cm H2O. To simulate the lung mechanics of an infant in respiratory distress, tests were conducted on the IngMar ASL 5000 Test Lung simulator. Resistance was set at 100 cm H2O/L/s, and compliance was tested at 0.5, 1.0, and 2.0 mL/cm H2O to simulate 3 different patients. RESULTS The delivered pressure waveforms and compliance curves of the bubble NIV device are similar to those of the Hamilton and Dräger ventilators. The mean ± SD differences between delivered versus set pressure gradient (ie, the difference between the high delivered pressure and the low delivered pressure) for each treatment modality across the various values of compliance were -2 ± 8% for the bubble NIV device, 3 ± 4% for the Dräger ventilator, and 7 ± 10% for the Hamilton ventilator. CONCLUSIONS The similarity of pressure waveforms and delivered tidal volumes in this simulated clinical scenario suggest that the bubble NIV device may provide comparable efficacy compared with traditional ventilator treatment for a range of patients. This may provide clinicians in resource-limited settings with an additional, simple, nonelectric treatment modality for the management of infant respiratory distress. Copyright © 2020 by Daedalus Enterprises.BACKGROUND Obese subjects are at higher risk of development and progression of ARDS. There are limited data regarding mechanical ventilation practices and use of adjunctive therapies in subjects with ARDS across different obesity classes. We hypothesized that the adherence to lung-protective ventilation would be worse with rising body mass index class in patients with ARDS. METHODS We conducted a retrospective observational study of subjects with ARDS. We evaluated the differences in ventilator settings, airway pressures, gas exchange, use of rescue therapies, length of hospital stay, and mortality among subjects based on the obesity classes of the WHO. RESULTS The study included 613 subjects with ARDS 21.4% were normal weight, 25% were overweight, and 53.7% were obese; 33.3% of the obese subjects met criteria for class I-II obesity, while 20.4% were class III obese (morbid obesity). On day 1, 53% of subjects with class III obesity had tidal volumes > 8 mL/kg, compared to 26% of the subjects with normal weight.