Novel coronavirus SARS-CoV-2 has created unprecedented healthcare challenges. Neurologic deficits are often an important presenting symptom. To date, the only reported post-infectious COVID-19 manifestations of neurologic disease include cognitive deficits and dysfunction of the peripheral nervous system. Here we report that seizure can also be a post-COVID-19 or "long-COVID" complication. We present a 71-year-old man with hypertension, diabetes mellitus, and COVID-19 diagnosed by RT-PCR who initially presented with posterior circulation stroke-like symptoms, which completely resolved after emergent thrombolysis. https://www.selleckchem.com/products/bgb-290.html Six days later, the patient returned with seizure activity, supported by radiographic and electroencephalographic studies. Notably, he was negative for SARS-CoV-2, and no other provoking factor was uncovered after a comprehensive work-up. To our knowledge, this is the first report of post-infectious seizures after a case of COVID-19, highlighting the potential importance of monitoring for neurologic symptoms in COVID-19 patients, even after convalescence. Aperture-based complexity metrics have been suggested as a method to score complexity of volumetric modulated arc therapy (VMAT) plans. The purpose of this study was to evaluate the edge area metric (EAM) for clinical VMAT plans on a control point and treatment plan level. EAM on a control point level was evaluated based on film measurements of 18 static beam openings originating from VMAT plans. EAM on a treatment plan level (arithmetic mean value of EAM scores for control points) was evaluated based on measurements with the Delta ® for 200 VMAT plans for four different treatment sites pelvic, thorax, head and neck, and prostate. Measurements were compared to calculations and dose difference and gamma pass rates were evaluated. EAM scores on a control point level correlated with Pearson's r-values of -0.96 and -0.77 to dose difference and gamma pass rates, respectively. The prostate plans had the highest average EAM score. A connection between smaller PTVs and higher EAM scores was found. No correlation between the evaluation result and EAM on a plan level was found. EAM on a control point level was shown to correlate to the difference between measured and calculated 2D dose distributions of clinical VMAT beam openings. No correlation was found for EAM on a plan level for clinical treatment plans. EAM on a control point level was shown to correlate to the difference between measured and calculated 2D dose distributions of clinical VMAT beam openings. No correlation was found for EAM on a plan level for clinical treatment plans. In locally advanced prostate cancer (PC), androgen deprivation therapy (ADT) in combination with whole prostate radiotherapy (RT) is the standard treatment. ADT affects the prostate as well as the tumour on multiparametric magnetic resonance imaging (MRI) with decreased PC conspicuity and impaired localisation of the prostate lesion. Image texture analysis has been suggested to be of aid in separating tumour from normal tissue. The aim of the study was to investigate the impact of ADT on baseline defined MRI features in prostate cancer with the goal to investigate if it might be of use in radiotherapy planning. Fifty PC patients were included. Multiparametric MRI was performed before, and three months after ADT. At baseline, a tumour volume was delineated on apparent diffusion coefficient (ADC) maps with suspected tumour content and a reference volume in normal prostatic tissue. These volumes were transferred to MRIs after ADT and were analysed with first-order -and invariant Haralick -features. At baseline, the median value and several of the invariant Haralick features of ADC, showed a significant difference between tumour and reference volumes. After ADT, only ADC median value could significantly differentiate the two volumes. Invariant Haralick -features could not distinguish between baseline MRI defined PC and normal tissue after ADT. First-order median value remained significantly different in tumour and reference volumes after ADT, but the difference was less pronounced than before ADT. Invariant Haralick -features could not distinguish between baseline MRI defined PC and normal tissue after ADT. First-order median value remained significantly different in tumour and reference volumes after ADT, but the difference was less pronounced than before ADT. Artefacts caused by dental amalgam implants present a common challenge in computed tomography (CT) and therefore treatment planning dose calculations. The goal was to perform a quantitative image quality analysis of our Artifact Management for Proton Planning (AMPP) algorithm which used gantry tilts for managing metal artefacts on Head and Neck (HN) CT scans and major vendors' commercial approaches. Metal artefact reduction (MAR) algorithms were evaluated using an anthropomorphic phantom with a removable jaw for the acquisition of images with and without (baseline) metal artifacts. AMPP made use of two angled CT scans to generate one artifact-reduced image set. The MAR algorithms from four vendors were applied to the images with artefacts and the analysis was performed with respective baselines. Planar HU difference maps and volumetric HU differences were analyzed. AMPP algorithm outperformed all vendors' commercial approaches in the elimination of artefacts in the oropharyngeal region, showing the lowest percent of pixels outside +- 20 HU criteria, 4%; whereas those in the MAR-corrected images ranged from 26% to 67%. In the region of interest within the affected slices, the commercial MAR algorithms showed inconsistent performance, whereas the AMPP algorithm performed consistently well throughout the phantom's posterior region. A novel MAR algorithm was evaluated and compared to four commercial algorithms using an anthropomorphic phantom. Unanimously, the analysis showed the AMPP algorithm outperformed vendors' commercial approaches, showing the potential to be broadly implemented, improve visualizations in patient anatomy and provide accurate HU information. A novel MAR algorithm was evaluated and compared to four commercial algorithms using an anthropomorphic phantom. Unanimously, the analysis showed the AMPP algorithm outperformed vendors' commercial approaches, showing the potential to be broadly implemented, improve visualizations in patient anatomy and provide accurate HU information.