Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
To assess the influence of multiple uses on the cyclic flexural fatigue and torsional resistance of Reciproc R25 (REC) instruments. 256 canals (2 for each mandibular molar) were prepared using Reciproc R25 instruments. A total of 96 25-mm-long Reciproc R25 instruments were divided in six groups (n=8) on the basis of different number of canal shaped new instruments (control group), 1, 2, 3, 4 or 6 canals shaped during simulated clinical use for other groups respectively. Sixteen files were used for each of the six groups (8 instruments for cyclic fatigue test and 8 ones for torsional test). Times to fracture (TtF) for cyclic fatigue and ultimate torsional strength and angle of rotation to fracture for torsional resistance were recorded. Data were statistically evaluated by the analysis of variance (ANOVA) with P<.05. As for cyclic fatigue resistance, there was no significant difference between new REC and REC used in one, two and three canals respectively (P>.05). REC used in four and six canals showed significant lower times to fracture when compared with other groups (P<.05) with REC used in six canals showing the significant lowest times to fracture (P<.05). Considering torsional resistance parameters, no significant difference was observed between the new and used instruments (P>.05). REC25 files showed a significant decrease in cyclic fatigue resistance only when used in four or more molar canals while their torsional behavior was not affected by multiple uses. REC25 files showed a significant decrease in cyclic fatigue resistance only when used in four or more molar canals while their torsional behavior was not affected by multiple uses. The aim of this study is to highlight the connection between orthodontic difficulty before surgical treatment and in the transient malocclusion as evaluated by the mean of the ICON score and total treatment time in SFA. For each patient, the ICON score was evaluated pre-operatively and on the 3rd post-operative day in order to assess the orthodontic difficulty of pre-surgical occlusion and the transient malocclusion. Our group of patients at the preoperative stage showed score values between hard and very hard with only one patient scored as "easy" and nine "medium" patients. All scores lowered after surgical treatment. This confirms that the surgery first approach can change a malocclusion from not orthodontically treatable to an orthodontically treatable one. In our study, this was objectified by improvements in the ICON score. In the conventional three-phase approach of orthognathic surgery the total treatment time found in literature is around 18-36 months. In our study, even the most difficult cases do not have a duration of more than 15 months This demonstrates that the surgery-first approach can reduce the total treatment time even in more severe cases. Our group of patients at the preoperative stage showed score values between hard and very hard with only one patient scored as "easy" and nine "medium" patients. All scores lowered after surgical treatment. This confirms that the surgery first approach can change a malocclusion from not orthodontically treatable to an orthodontically treatable one. In our study, this was objectified by improvements in the ICON score. In the conventional three-phase approach of orthognathic surgery the total treatment time found in literature is around 18-36 months. In our study, even the most difficult cases do not have a duration of more than 15 months This demonstrates that the surgery-first approach can reduce the total treatment time even in more severe cases.Technological development has interested most of the dentistry's branches leading to the use of other medical technologies non previously involved in dental practice. This study aims to evaluate the potential role of non-invasive imaging techniques in oral pathology workflow. Optical coherence tomography has been described by several authors as a promising aid for differential diagnosis of autoimmune diseases and to detect epithelial subversion of the oral mucosa before the clinical manifestation of oral mucositis. High-frequency ultrasound offers the chance to assess lesional dimensions both in benign and malignant lesions with a high dimensional reliability compared with histopathology. Reflectance confocal microscopy seems to be helpful in the early detection of cytological changes due to its high resolution, suggesting a more interesting role in the analysis of malignant lesions. The study presented highlighted the potential role of noninvasive in vivo imaging although further studies are needed for the further validation of these techniques. The objective of this study was to retrospectively evaluate the success and survival rate of implants with different types of prosthetic connections inserted in the posterior maxilla in native bone or in sinuses previously grafted with different biomaterials. A total of 310 implants inserted in 113 patients were evaluated, 87 of which were inserted in association with grafted maxillary sinuses (56 morse taper (MT) implants and 31 external hexagon (EH) implants) in 37 patients, and 223 implants were inserted in native bone areas (112 MT and 111 EH implants) in 76 patients. Peri-implant clinical analyses were performed (bleeding on probing, probing depth, clinical insertion level, peri-implant marginal level, and the presence of mobility or suppuration), and the radiographic bone level was evaluated. Two implants were lost, yielding a survival rate of 99.35 %. The MT implants had lower probing depths and peri-implant bone levels than the EH implants in both grafted areas and native bone areas (p <0.05). https://www.selleckchem.com/products/skf96365.html No statistically significant differences in any parameter evaluated were found between implants inserted in native bone and those inserted in grafting areas. EH implants inserted in native bone areas showed higher periimplantitis rates. It can be concluded that the MT implants connection reduce periimplant bone loss, but implants inserted in maxillary sinuses previously grafted with osteoconductive biomaterials do not predispose patients to peri-implant bone loss. It can be concluded that the MT implants connection reduce periimplant bone loss, but implants inserted in maxillary sinuses previously grafted with osteoconductive biomaterials do not predispose patients to peri-implant bone loss.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत