Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
The 2 groups did not differ significantly in baseline characteristics and surgical data. Postoperative visual analog scale score for low back pain and leg pain were significantly higher in the P-group than in the G-group (low back pain G-group, 1.7±1.9 vs. P-group, 5.2±2.5, P<0.001; leg pain G-group, 1.4±2.0 vs. P-group, 5.5±2.6, P<0.001). Multivariate regression analysis revealed that postoperative vertebral fracture (P=0.049; odds ratio, 3.096; 95% confidence interval, 1.004-9.547) and reoperation (P=0.025; odds ratio, 5.692; 95% confidence interval, 1.250-25.913) were significantly associated with the patient satisfaction after lumbar spinal surgery. Postoperative vertebral fracture and reoperation were found to be risk factors for poor patient satisfaction after lumbar spinal surgery in elderly patients, which suggests a need for careful treatment of osteoporosis in addition to careful determination of surgical indication and procedure in elderly patients. Level III. Level III. The apparently physiological kinematics of the bicruciate-stabilized total knee arthroplasty (BCS TKA) systems have been attributed to the anterior and posterior post-cam mechanism. Although comparisons between TKA designs with either a retained or a sacrificed cruciate ligament have been conducted, we are not aware of any analyses of 2 implants with identical bearing geometry but different cruciate-ligament strategies under equal loading conditions. Knowledge about the kinematic effect of the different cruciate ligament strategies would potentially be valuable to facilitate preoperative planning and decision-making with regard to selecting the most appropriate implant for a patient. This retrospective study included 20 patients 10 treated with a BCS and 10 treated with a cruciate retaining (CR) TKA. Fluoroscopic analyses during high-flexion activities (unloaded flexion-extension and loaded lunge) were conducted at 24 months postsurgery. https://www.selleckchem.com/products/rilematovir.html All patients completed the Knee Society Score, Forgotten Joint Scoremplete description of levels of evidence. The relationship between preoperative subchondral bone marrow edema (BME) in the osteoarthritic knee and pain has been established. However, little is known about the influence of preoperative BME on outcomes after medial opening-wedge high tibial osteotomy (MOHTO). The purpose of this study was to clarify the association between preoperative BME severity and clinical outcomes after MOHTO at intermediate follow-up. We reviewed the cases of 105 consecutive patients who underwent MOHTO for osteoarthritis of the knee with preoperative subchondral BME in the medial aspect of the tibia between January 2005 and December 2015. BME was evaluated using magnetic resonance imaging (MRI). The sizes of the BME lesions were determined on the basis of the maximum diameter and were classified as small (<1 cm), medium (<2 cm), large (<4 cm), or very large (diffuse; >4 cm). Associations between preoperative BME severity and postoperative outcomes at a mean follow-up of 6.2 years (range, 2.0 to 14.3 years) were operative outcomes. MOHTO showed good functional outcomes, a low major complication rate, and an excellent survival rate with a mean follow-up of 6.2 years, regardless of the degree of preoperative BME. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. A minority of proximal humeral fractures extend into the diaphysis and their optimal treatment remains controversial. We evaluated the outcomes and risk of complications in patients with these injuries, treated by a protocol of open reduction and long locking plate fixation (LPF). Between 2007 and 2014, all locally resident patients with a proximal humeral fracture extending into the diaphysis were referred to a specialist shoulder clinic. Operative treatment using a protocol of open reduction and LPF was offered to medically fit patients. Those with 2-year radiographic follow-up were included in the study, and standardized assessments of clinical and radiographic outcomes were performed during the first 2 years postoperatively. At a mean of 8.8 years (range, 5 to 12 years) after LPF, the functional outcomes and satisfaction of surviving, cognitively intact patients were assessed with a questionnaire study. One hundred and two patients met the inclusion criteria; the majority were older women who had incurred the injury during a simple fall. Fractures were divided into 2 types depending on the pattern of diaphyseal extension. The pain levels, functional scores, and satisfaction with treatment were satisfactory both at the 2-year follow-up and at the longer-term follow-up at a mean of 8.8 years postsurgery. Complications were predominantly due to postsurgical stiffness (in 7 patients, with 3 undergoing additional surgery) and nonunion or fixation failure (in 7 patients, with 6 undergoing additional surgery). Proximal humeral fractures with diaphyseal extension are rare. The results of our study support the use of LPF in medically stable patients in centers with the expertise to perform these procedures. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.Point-of-care ultrasound (POCUS) use is rapidly expanding as a practice in adult and pediatric critical care environments. In January 2020, the Joint Commission endorsed a statement from the Emergency Care Research Institute citing point-of-care ultrasound as a potential hazard to patients for reasons related to training and skill verification, oversight of use, and recordkeeping and accountability mechanisms for clinical use; however, no evidence was presented to support these concerns. Existing data on point-of-care ultrasound practices in pediatric critical care settings verify that point-of-care ultrasound use continues to increase, and contrary to the concerns raised, resources are becoming increasingly available for point-of-care ultrasound use. Many institutions have recognized a successful approach to addressing these concerns that can be achieved through multispecialty collaborations.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत