Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
Body-focused repetitive behavior disorders (BFRBs) include Trichotillomania (TTM; Hair pulling disorder) and Excoriation (Skin Picking) Disorder (SPD). These conditions are prevalent, highly heterogeneous, under-researched, and under-treated. In order for progress to be made in optimally classifying and treating these conditions, it is necessary to identify meaningful subtypes. 279 adults (100 with TTM, 81 with SPD, 40 with both TTM and SPD, and 58 controls) were recruited for an international, multi-center between-group comparison using mixture modeling, with stringent correction for multiple comparisons. The main outcome measure was to examine distinct subtypes (aka latent classes) across all study participants using item-level data from gold-standard instruments assessing detailed clinical measures. Mixture models identified 3 subtypes of TTM (entropy 0.98) and 2 subtypes of SPD (entropy 0.99) independent of the control group. Significant differences between these classes were identified on measures of disability, automatic and focused symptoms, perfectionism, trait impulsiveness, and inattention and hyperactivity. These data indicate the existence of three separate subtypes of TTM, and two separate subtypes of SPD, which are distinct from controls. The identified clinical differences between these latent classes may be useful to tailor future treatments by focusing on particular traits. Future work should examine whether these latent subtypes relate to treatment outcomes, or particular psychobiological findings using neuroimaging techniques. An improper restoration color match to the adjacent natural teeth can jeopardize esthetic success. The type of resin-matrix ceramic (RMC), the shade of the underlying foundation, and the shade of cement may affect the optical behavior of RMC materials, but studies on this issue are lacking. The purpose of this invitro study was to assess the cumulative effect of different shades of composite resin foundation (CRF) and cement on the optical behaviors of 3 different RMCs. Forty-five rectangular RMC specimens (14×12×1 mm, shade A2) were prepared from 3 different blocks, including a polymer-infiltrated ceramic network (Vita Enamic [VE]), a resin nanoceramic (Lava Ultimate [LU]), and a flexible nanoparticle-filled resin (GC Cerasmart [GC]) (n=15 per RMC block). CRFs (14×12×4 mm) were fabricated in white and dentin shades (n=1 per composite resin shade). Cement specimens (G-CEM LinkForce) were prepared from 3 shades (A2, opaque [OP], and translucent [TR]) (n=15 per shade). For control groups, 3 rectangular RMhen used with the same shade on the dentin foundation, this cement produced clinically acceptable results. Opaque cement on the white foundation led to the highest ΔE00 values in the resultant colors of all RMC groups. When used with the same shade on the dentin foundation, this cement produced clinically acceptable results.This technical report presents a color-coded classification system for identifying a dental abutment screw head design to its corresponding implant driver system with polytetrafluorethylene (PTFE) tape. This proposed standardization should simplify the restoration and retrieval of implant components.A surgical extrusion technique was used to provide a ferrule for a tooth with significant tooth structure loss and an oblique coronal fracture. The maxillary lateral incisor was surgically repositioned coronally to provide sufficient dentinal wall for a good prognosis of the restorative treatment. The procedure is conservative and relatively straightforward and can be performed rapidly with minimal patient discomfort. Studies of interproximal contact loss (ICL)associated with implant-supported fixed prostheses (ISFPs)have typically used dental floss or metal strips to determine ICL and have shown a high prevalence of 34% to 66%, which does not match the authors' experience. Moreover, the implant prosthetic factors contributing to ICL have seldom been reported. The purpose of this clinical study was to examine follow-up radiographs of ISFPs to determine the prevalence of open contacts between the ISFP and adjacent teeth and to assess the risk factors associated with ICL at patient, implant prosthesis, and adjacent tooth levels. Patients treated with ISFPs at a single clinical center were included. Digital radiographs obtained at the time of ISFP delivery and subsequent follow-up were assessed, and a total of 180 ISFPs with 296 interproximal contacts in 147 patients were screened for analyses. The prevalence and risk factors of ICL at the levels of patient (age, sex, diabetes, smoking, and bruxism), implant prosthesis al spacing had the highest adjusted odds ratio of 20.88 (P=.002). Most of the ICL were found at the mesial side of ISFPs, and the odds of ICL was significant in participants with longer follow-up periods. https://www.selleckchem.com/Proteasome.html Internal hexagonal connections reported relatively lower risk than others. Factors relevant to the anterior component of occlusal force, such as male sex, contralateral spacing at adjacent tooth, and proximal contact of ISFP with resin filling, seem to be high risk factors for ICL. Most of the ICL were found at the mesial side of ISFPs, and the odds of ICL was significant in participants with longer follow-up periods. Internal hexagonal connections reported relatively lower risk than others. Factors relevant to the anterior component of occlusal force, such as male sex, contralateral spacing at adjacent tooth, and proximal contact of ISFP with resin filling, seem to be high risk factors for ICL. Evidence for the accuracy of a recently introduced intraoral scanner is lacking. The purpose of this invitro study was to evaluate and compare the trueness (validity) and precision (reliability) of 2 intraoral scanners by scanning a quadrant and a sextant. A maxillary typodont with plastic teeth made from a shade A3 polymethyl methacrylate was scanned (n=10) with each intraoral scanner (Planmeca Emerald and 3Shape TRIOS 3) to obtain sextant and quadrant scans. Control scans were made with an industrial optical scanner. The scans were analyzed with a 3D reverse engineering software program and an independent samples t test and general linear model 2-way analysis of variance (α=.05). The 3Shape TRIOS 3 scanner showed no significant difference between the sextant and quadrant scans in trueness (P=.118) or in precision (P<.285). The Emerald scanner had statistically significant higher trueness for the sextant scan (P=.007). The 3Shape TRIOS 3 scanner had better performance in trueness and precision when compared with the Emerald scanner.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत