Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
e., potassium or L-type calcium currents, M2muscarinic cholinergic or β1-adrenergic receptor signaling) can also lead to cardiac arrhythmia. Drug-induced arrhythmias, caused, for example, by corticosteroids, methotrexate, chloroquine, are also observed among AD patients. The most common arrhythmia in most AD presentations is atrial arrhythmia (primarily atrial fibrillation), expect for sarcoidosis and scleroderma, which are characterized by a higher burden of ventricular arrhythmia. Arrhythmia-associated mortality is highest among patients with sarcoidosis and lowest among those with AS; there are scant data related to mortality in patients with psoriasis, CD, and IBD.Corticofugal projections to neurons in the medullary dorsal horn, i.e., the trigeminal spinal subnucleus caudalis (Sp5C), are thought to play a critical role in regulating nociceptive information processing in the trigeminal nervous system. The Sp5C consists of 5 layers, each of which exhibits its own characteristic features of cellular organization. Therefore, the layers receiving corticofugal projections must be identified when discussing the role of the cerebral cortex in nociception arising from the trigeminal nerve. It is also necessary to discriminate between layers of the Sp5C where corticofugal projections terminate, because the Sp5C involves glutamatergic neurons and GABAergic/glycinergic neurons, which correspond to excitatory and inhibitory neurons, respectively. This review summarizes descending projections from the cerebral cortex, including the primary and secondary somatosensory and insular cortices, to the Sp5C.Immunoglobulin G4-related disease (IgG4-RD) is a fibroinflammatory condition which involves various organs. This is a very rare case of IgG4-related lung disease (IgG4-RLD) with the invasion into diaphragm. The patient was a 71-year-old man with a long-term exposure to asbestos who had a mass shadow in the left lower lung lobe, which was suspected to invade the left diaphragm on computed tomography (CT). Positron emission tomography (PET)/CT also presented an avid intake of fluorodeoxyglucose in the mass, which suspected lung cancer. Although bronchoscopic biopsy could not lead to the definite diagnosis, we performed left lower lobectomy combined with the resection of left diaphragm. The specimen showed the features of IgG4-RLD on pathology the vein stenosis and fibrosis around the vein, the infiltration of IgG4-positive cells, and IgG cells to IgG4 cells ratio of 40%. Furthermore, there were inflammatory cells infiltrating to the diaphragm.Low-energy X-ray imaging of secondary electron bremsstrahlung X-rays emitted during carbon-ion irradiation is a promising method for range estimation and could be used for imaging with almost clinical dose levels of carbon ion. However, the number of counts in images with clinical dose levels is relatively small, making it difficult to obtain precise range estimations. Since improving the sensitivity of the X-ray camera may solve this issue, we developed two new types of X-ray cameras. One uses a 1-mm thick, 40 mm × 40-mm cerium-doped yttrium aluminum perovskite (YA1O3 YAP(Ce)) scintillator plate combined with a 2-inch square flat panel photomultiplier tube (FP-PMT) contained in a 2-cm thick tungsten shield with a pinhole collimator positioned 50 mm from the scintillator; the other uses a 0.5-mm thick, 20 mm × 20-mm YAP(Ce) scintillator plate combined with a 1-inch square position sensitive photomultiplier tube (PS-PMT) contained in the same tungsten shield with a pinhole collimator, but with the scintillator positioned closer (30 mm) to the pinhole collimator to obtain a similar field-of-view (FOV). For both cameras, we used a wider angle (~55 degrees) pinhole collimator to measure the phantom closer to improve sensitivity. Although the 40 mm × 40-mm YAP(Ce) camera had high system spatial resolution, the background count fractions were high and produced a high count area at the center of the images due to the pulse pileup of the signals. With the 20 mm × 20-mm YAP(Ce) camera, we obtained X-ray images with low background counts without a high count area at the image center. By smoothing the measured images, we were able to estimate the ranges even for clinical dose levels. We therefore confirmed that one of our newly developed YAP(Ce) cameras had high sensitivity and is promising for the imaging of secondary electron bremsstrahlung X-rays during irradiation of carbon ions in clinical conditions. © 2020 Institute of Physics and Engineering in Medicine.In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on Time-Of-Flight (TOF)-resolved Prompt Gamma (PG) detection in a single proton counting regime. In a proof of principle experiment, different types of monolithic scintillating gamma detectors are read in time coincidence with a diamond-based beam hodoscope, in order to build TOF spectra of PG generated in a target presenting an air cavity of variable thickness. Since the measurement was carried out at low beam currents ( less then 1 proton/bunch) it was possible to reach excellent coincidence time resolutions, of the order of 100 ps (σ). https://www.selleckchem.com/products/gsk2879552-2hcl.html Our goal is to detect possible deviations of the proton range with respect to treatment planning within a few intense irradiation spots at the beginning of the session and then carry on the treatment at standard beam currents. The measurements were limited to 10 mm proton range shift. A Monte Carlo simulation study reproducing the experiment has shown that a 3 mm shift can be detected at 2σ by a single detector of ∼ 1.4 × 10-3absolute detection efficiency within a single irradiation spot (∼108 protons) and an optimised experimental set-up. © 2020 Institute of Physics and Engineering in Medicine.OBJECTIVE The efficacy of deep brain stimulation can be limited by factors including poor selectivity of stimulation, targeting error, and complications related to implant reliability and stability. We aimed to improve surgical outcomes by evaluating electrode leads with smaller diameter electrode and microelectrodes incorporated which can be used for assisting targeting. APPROACH Electrode arrays were constructed with two different diameters of 0.65 mm and the standard 1.3 mm. Micro-electrodes were incorporated into the slim electrode arrays for recording spiking neural activity. Arrays were bilaterally implanted into the medial geniculate body (MGB) in nine anaesthetised cats for 24-40 hours using stereotactic techniques. Recordings of auditory evoked field potentials and multi-unit activity were obtained at 1 mm intervals along the electrode insertion track. Insertion trauma was evaluated histologically. MAIN RESULTS Evoked auditory field potentials were recorded from ring and micro-electrodes in the vicinity of the medial geniculate body.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत