Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
The transferability of the method to another instrument was also demonstrated. For both analyzers, concentrations of validation samples were within 5% of those determined through wet chemical analysis. Pre-requisites and recommendations for the application of the method as well as its applicability to both short- and long-term release rate studies in the field are also presented and discussed.Developing effective ways for controlling the quality of natural products that are sold in high volume worldwide is currently one of the most urgent goals of analytical chemistry. Black pepper (Piper nigrum) is a major spice that constitutes 34% of the global spice market. Black pepper is highly prone to quality variations, arising from alteration of the piperine content. Miniaturized NIR spectroscopy offers a high-throughput, cost-effective and laboratory independent technique for quality control of black pepper. Handheld NIR spectrometers differ in the implemented technology, with impact on their analytical performance and unit cost. In this work, the performance of three miniaturized NIR instruments in quantification of piperine in whole and milled seeds of black pepper was investigated. With HPLC method used as the reference analysis, partial least squares regression (PLSR) models were constructed for NIR spectra while the prediction accuracy with respect to the spectrometer used was monitored through roohe difference in the analytical performance of the compared spectrometers with statistical parameters of the calibration models below acceptable levels.Anabaenopeptins (APs) are bioactive cyanopeptides of emerging concern produced by cyanobacteria. The research for analytical development has recently gained in importance due to their abundance in toxic cyanobacterial blooms. A new commercial enzyme-linked immunosorbent assay kit for the determination of total APs (APtot ELISA) has been released promising a rapid response with good cost efficiency for the routine monitoring of uncommon cyanopeptides. The present study explores the suitability of this new kit in comparison with a validated quantitative analytical method based on liquid chromatography coupled to mass spectrometry (LC-MS). The validation results were comparable with both methods for accuracy, precision, and calibration. Method detection limits were more sensitive using LC-MS specifically evaluated at 0.011 and 0.013 μg L-1 for AP-A and B respectively, compared to APtot ELISA evaluated at 0.10 μg L-1 for total of the two. For APtot ELISA, results were independent from the matrix; however, a systematic signal response was measured in blanks, requiring a blank subtraction in data treatment. Cross-reactivity of APtot ELISA was investigated by analyzing ten cyanopeptides selected for their abundance and diversity. Cyanopeptolin A (CP-A), nodularin-R (NOD), microcystin (MC)-RR, [Asp3]RR, and HilR showed cross-reactivity with an average overestimation going from 25 to 66%. Considering the contribution of cross-reactive cyanopeptides, thirteen lake samples out of fifteen showed higher concentrations using APtot ELISA with overestimation values up to 2261% compared to LC-MS. In light of this study results, LC-MS should still be preconized for the study and monitoring of APs when sensitivity and specificity are needed.The development of flexible and robust plasmonic substrates has become a hot research topic in simplifying and extending the application of surface-enhanced Raman scattering (SERS) technique for real-world analysis. In this work, a facile method to fabricate an Au@Ag nanoparticle array sandwiched between the adhesive acrylic polymer tape and polyethene terephthalate (PET) film (T/Au@Ag/PET) as a high-performance SERS chip was reported for nondestructive detection of thiram on fruit peels. For this SERS chip, the ordered Au@Ag nanoparticle array formed by the self-assembly method was closely-packed, which generated high-density sub-3-nm gaps and could produce high reproducible and sensitive SERS enhancement effects. The measurement of crystal violet with the limit of detection of 7.24 × 10-10 M was realized by targeting Raman shift at 1177 cm-1. https://www.selleckchem.com/products/paeoniflorin.html Moreover, the excellent flexible feature of acrylic polymer tape enabled the substrate to withstand a tensile strain value of 20% for three cycles without significantly losing its SERS activity. By covering with a PET film, the SERS chip could maintain 87% SERS activity after storage for 60 days in the air environment, and could well withstand the influence of harsh conditions such as high temperature and ultrasound treatments. As a proof of the concept, the SERS tape was directly used to detect thiram on apple, tomato, and cucumber peels via a simple sampling-and-detection procedure, and the detection limit of 5 ng/cm2 was achieved. The T/Au@Ag/PET SERS chip should hold a promising candidate for food safety analysis in the future.Organosilanes are used in a broad range of industrial, cosmetic, and personal care products. They serve as bridges between inorganic or organic substrates and organic/polymeric matrices. They are also versatile intermediates and can be used for a variety of synthetic applications. They do not exist naturally and have to be synthesized. Evaluation of intermediates and products resulting from the synthesis processes of organosilanes can be challenging. In this study, gas chromatography with vacuum ultraviolet spectroscopic detection (VUV) was used to analyze Si-containing compounds that are commercially available or were synthetically prepared. VUV measures full scan absorption in the range of 120-240 nm, a region that provides unique absorption signatures for chemical compounds. VUV absorption spectra of organosilanes showed rich and featured characteristics in this wavelength range. Theoretical computations of VUV absorption spectra based on time-dependent density functional theory were also explored as a complementary tool for identification. In addition, the synthesis process of isomeric benzodioxasiline compounds (ortho-, meta-, and para-) was monitored by GC-VUV. It was demonstrated that GC-VUV can be used for easy and rapid differentiation of organosilanes, including structural isomers.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत