Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
of CNI. Normothermic machine perfusion (NMP) provides a promising strategy for preservation and conditioning of marginal organ grafts. However, at present high logistic effort limits normothermic renal perfusion to a short, postponed machine perfusion at site of the recipient transplant center. Thus, organ preservation during transportation still takes place under hypothermic conditions, leading to significantly reduced efficacy of NMP. Recently it was shown that gentle and controlled warming up of cold stored kidneys compensates for hypothermic induced damage in comparison to end ischemic NMP. This study aims to compare controlled oxygenated rewarming (COR) with continuous up- front normothermic perfusion in a porcine model of transplantation. Following exposure to 30 minutes of warm ischemia kidneys (n=6/group) were removed and either cold stored for 8 hours (CS), cold stored for 6 hours with subsequent controlled rewarming up to 35 °C for 2 hours (COR) or directly subjected to 8 hours of continuous normothermic machine perfusion (NMP). Kidney function was evaluated using a preclinical autotransplant model with follow up for 7 days. NMP and COR both improved renal function in comparison to CS and displayed similar serum creatinine and urea levels during follow up. COR resulted in less tenascin C expression in the tissue compared to CS, indicating reduced proinflammatory upregulation in the graft by gentle rewarming. COR seems to be a potential alternative in clinical application of NMP, thereby providing logistic ease and usability. COR seems to be a potential alternative in clinical application of NMP, thereby providing logistic ease and usability.Targeted blood pressure (BP) control is a goal of left ventricular assist device medical management, but the interpretation of values obtained from noninvasive instruments is challenging. In the MOMENTUM 3 Continued Access Protocol, paired BP values in HeartMate 3 (HM3) patients were compared from arterial (A)-line and Doppler opening pressure (DOP) (319 readings in 261 patients) and A-line and automated cuff (281 readings in 247 patients). Pearson (R) correlations between A-line mean arterial (MAP) and systolic blood pressures (SBP) were compared with DOP and cuff measures according to the presence (>1 pulse in 5 seconds) or absence of a palpable radial pulse. There were only moderate correlations between A-line and noninvasive measurements of SBP (DOP R = 0.58; cuff R = 0.47) and MAP (DOP R = 0.48; cuff R = 0.37). DOP accuracy for MAP estimation, defined as the % of readings within ± 10 mmHg of A-line MAP, decreased from 80% to 33% for DOP ≤ 90 vs. >90 mmHg, and precision also diminished (mean absolute difference [MAD] increased from 6.3 ± 5.6 to 16.1 ± 11.4 mmHg). Across pulse pressures, cuff MAPs were within ±10 mmHg of A-line 62.9%-68.8% of measures and MADs were negligible. The presence of a palpable pulse reduced the accuracy and precision of the DOP-MAP estimation but did not impact cuff-MAP accuracy or precision. In summary, DOP may overestimate MAP in some patients on HM3 support. Simultaneous use of DOP and automated cuff and radial pulse may be needed to guide antihypertensive medication titration in outpatients on HM3 support.We compared the effects on the nutritional condition and health-related quality of life (HR-QoL) of the treatment of patients with on-line hemodiafiltration (OL-HDF) and conventional hemodialysis (CHD) using a superflux dialyzer. In total, 47 maintenance (M) HD patients were treated by CHD with a high-flux dialyzer for the first 4 months (1st CHD) and were then switched to predilution OL-HDF for the next 4 months (OL-HDF), after which CHD was resumed for the last 4 months (2nd CHD). We assessed the clinical parameters, fat mass value, muscle mass value, and HR-QoL. In patients with low serum albumin levels, these levels significantly (p less then 0.05) increased in the OL-HDF period. Moreover, the fat mass values significantly (p less then 0.05) increased in patients with decreased fat mass values in the OL-HDF period. Although there was no significant difference in the patients with higher scores of physical functioning, role physical, vitality, and social functioning, patients with lower scores in the 1st CHD period had significantly increased (p less then 0.05) in the OL-HDF period. In this crossover study, we revealed that OL-HDF treatment significantly improved the nutritional conditions and HR-QoL scores compared with the improvement observed after CHD with a superflux dialyzer, especially for maintenance hemodialysis patients with malnutrition and a low QoL.There is little research on factors that influence the choice of dialyzer in patients undergoing hemodialysis. In patients at risk for poorer outcomes, including those with hypoalbuminemia, understanding how this choice impacts clinical parameters could inform patient management. The objective of this real-world analysis was to evaluate the use and performance of four single-use (i.e., nonreuse [NR]), high-flux Optiflux dialyzers with varying surface areas (F160NR [1.5 m2], F180NR [1.7 m2], F200NR [1.9 m2], and F250NR [2.5 m2]) in patients (N = 271) with baseline hypoalbuminemia (≤3.5 g/dl) receiving hemodialysis at a medium-sized dialysis organization. Thrice weekly, in-center dialysis was delivered for 6 months without adjustments to the hemodialysis prescription. Larger dialyzers were more frequently used in men, patients with higher body mass indices, and those with diabetes. Increases in serum albumin from baseline (month 1) to month 6 (p less then 0.05) were observed with all dialyzer sizes. A mean increase in hemoglobin of 0.31 g/dl was also observed (p less then 0.001). Among patients exhibiting increased serum albumin levels (n = 177), reductions in the neutrophil-to-lymphocyte ratio, a marker of inflammation, were observed (mean 0.90; p less then 0.001). These results support the use of high-flux dialyzers in patients with hypoalbuminemia. Hibbert, JE, Klawiter, DP, Schubert, MM, Nessler, JA, and Asakawa, DS. Strength, cardiovascular fitness, and blood lipid measures in law enforcement personnel after a 12-week health promotion program. J Strength Cond Res XX(X) 000-000, 2021-Law enforcement personnel often have high rates of cardiovascular disease and injury. Health promotion programs have been found to successfully encourage behavior change among law enforcement personnel, but these programs can often be intensive and expensive. https://www.selleckchem.com/ Thus, the purpose of this study was to examine the efficacy of a health promotion program on body composition, metabolic health, muscle strength, and cardiovascular endurance in law enforcement personnel. Active duty officers from a local law enforcement agency were invited to participate in a 12-week health promotion program that included activity tracking and exercise and nutrition education. Eighteen subjects underwent measurements of body composition, V[Combining Dot Above]O2max through treadmill test, knee extensor strength, and blood lipids.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत