Yam Code
Sign up
Login
New paste
Home
Trending
Archive
English
English
Tiếng Việt
भारत
Sign up
Login
New Paste
Browse
Crouzon syndrome presents with craniofacial deformities due to early fusion of cranial sutures. Deviation of the nasal septum could be seen clinically in Crouzon syndrome. Cerebrospinal fluid leaks (CSF) after septoplasty are extremely rare and typically present with simple rhinorrhea, meningitis, and pneumocephalus. Herein, we report an adult patient with Crouzon syndrome who experienced CSF complication after septoplasty surgery.Supplemental Video CSF leak repair operation, http//links.lww.com/SCS/B930. Crouzon syndrome presents with craniofacial deformities due to early fusion of cranial sutures. Deviation of the nasal septum could be seen clinically in Crouzon syndrome. Cerebrospinal fluid leaks (CSF) after septoplasty are extremely rare and typically present with simple rhinorrhea, meningitis, and pneumocephalus. https://www.selleckchem.com/products/pepstatin-a.html Herein, we report an adult patient with Crouzon syndrome who experienced CSF complication after septoplasty surgery.Supplemental Video CSF leak repair operation, http//links.lww.com/SCS/B930. The use of virtual surgical planning and computer-aided design/computer-aided manufacturing has gained popularity in the surgical correction of craniosynostosis. This study expands the use of virtual surgical planning and computer-aided design/computer-aided manufacturing in cranial vault reconstruction by using these methods to reconstruct the anterior vault using a single endocortically-plated unit constructed from the posterior calvarium. This technique was designed to reduce the risk of undesirable contour deformities that can occur when multiple bone grafts are used to reconstruct the anterior vault and fronto-orbital rim. Six patients were included in this study, all of which had nonsyndromic craniosynostosis. Excellent aesthetic outcomes were obtained in all patients, without complication. Additionally, the placement of a single reconstructive unit constructed from the posterior calvarium was efficient, aesthetically pleasing, and minimized postoperative contour deformities secondary to bone gaps, recontour deformities secondary to bone gaps, resorption, and often palpable resorbable plates.Pharyngocutaneous fistula (PCF) is one of the most common but stranded complications for salvage laryngectomy. As for localized fistula, there is no convincing standard and method to cure. This paper described a patient who was submitted to extensive resection of mass in right lingual root, total laryngectomy, and pharyngoesophageal reconstruction with an anterolateral thigh flap (ALTF), because of recurred carcinoma of right lingual root which invaded bilateral epiglottis. 2 weeks after surgery, subsequent pharyngocutaneous fistula developed at the junction of the tracheostomy, and maintained over 2 months under conservative treatment. With the assistance of laryngoscope, inner and outer orificiums of fistula were found and sealed by bundled iodoform strip. 9 days after sealing, fistula had been already filled with fresh granulation tissue. During 2 years after surgery, the fistula area dose not recur. This technique provides a safe and effective way for sealing the inner and outer orificiums of fistula.Facial asymmetry is a challenge for surgeons. Some surgical strategies could be used involved soft or hard tissue of the face. The aim of this report is to show the use of patient specific implants (PSI) in a puzzle strategy based on computer aided design/computer aided manufacturer to solve a complex structural facial asymmetry after orthognathic surgery. Twenty-five-year-old male patient complain for facial asymmetry after orthognathic surgery; main deformity was related to the shape of mandibular bone in the ramus, angle, and body. After mirror image, was chose an augmentation in the right side using 2-pieces patient specific implants and the bone reduction in the vertical high of the mandibular body in the left side. Surgical technique was realized by intra oral approach installing the ramus segment at first approach and the body segment as second to obtain stability in the fitting implant-bone-implant; the left side was treated using a guide for osteotomy; after 1-year follow-up no infection or complication was observed and facial symmetry was obtained. It is possible to conclude that the puzzle technique using polyetheretherketone can be applied to obtain predictable results in a simple strategy to solve a complex problem. This study evaluated whether patients with a left-sided femoral neck fracture (FNF) treated with a sliding hip screw (SHS) had a higher implant failure rate than patients treated for a right-sided FNF. This was performed to determine the clinical relevance of the clockwise rotational torque of the femoral neck lag screw in a SHS, in relation to the rotational stability of left and right-sided FNFs after fixation. Data were derived from the FAITH trial and Dutch Hip Fracture Audit (DHFA). Patients with a FNF, aged ≥50, treated with a SHS, with at least 3-month follow-up data available, were included. Implant failure was analyzed in a multivariable logistic regression model adjusted for age, sex, fracture displacement, prefracture living setting and functional mobility, and American Society for Anesthesiologists Class. One thousand seven hundred fifty patients were included, of which 944 (53.9%) had a left-sided and 806 (46.1%) a right-sided FNF. Implant failure occurred in 60 cases (3.4%), of which 31 were left-sided and 29 right-sided. No association between fracture side and implant failure was found [odds ratio (OR) for left vs. right 0.89, 95% confidence interval (CI) 0.52-1.52]. Female sex (OR 3.02, CI 1.62-6.10), using a mobility aid (OR 2.02, CI 1.01-3.96) and a displaced fracture (OR 2.51, CI 1.44-4.42), were associated with implant failure. This study could not substantiate the hypothesis that the biomechanics of the clockwise screw rotation of the SHS contributes to an increased risk of implant failure in left-sided FNFs compared with right-sided fractures. Therapeutic Level II.See Instructions for Authors for a complete description of levels of evidence. Therapeutic Level II.See Instructions for Authors for a complete description of levels of evidence.
Paste Settings
Paste Title :
[Optional]
Paste Folder :
[Optional]
Select
Syntax Highlighting :
[Optional]
Select
Markup
CSS
JavaScript
Bash
C
C#
C++
Java
JSON
Lua
Plaintext
C-like
ABAP
ActionScript
Ada
Apache Configuration
APL
AppleScript
Arduino
ARFF
AsciiDoc
6502 Assembly
ASP.NET (C#)
AutoHotKey
AutoIt
Basic
Batch
Bison
Brainfuck
Bro
CoffeeScript
Clojure
Crystal
Content-Security-Policy
CSS Extras
D
Dart
Diff
Django/Jinja2
Docker
Eiffel
Elixir
Elm
ERB
Erlang
F#
Flow
Fortran
GEDCOM
Gherkin
Git
GLSL
GameMaker Language
Go
GraphQL
Groovy
Haml
Handlebars
Haskell
Haxe
HTTP
HTTP Public-Key-Pins
HTTP Strict-Transport-Security
IchigoJam
Icon
Inform 7
INI
IO
J
Jolie
Julia
Keyman
Kotlin
LaTeX
Less
Liquid
Lisp
LiveScript
LOLCODE
Makefile
Markdown
Markup templating
MATLAB
MEL
Mizar
Monkey
N4JS
NASM
nginx
Nim
Nix
NSIS
Objective-C
OCaml
OpenCL
Oz
PARI/GP
Parser
Pascal
Perl
PHP
PHP Extras
PL/SQL
PowerShell
Processing
Prolog
.properties
Protocol Buffers
Pug
Puppet
Pure
Python
Q (kdb+ database)
Qore
R
React JSX
React TSX
Ren'py
Reason
reST (reStructuredText)
Rip
Roboconf
Ruby
Rust
SAS
Sass (Sass)
Sass (Scss)
Scala
Scheme
Smalltalk
Smarty
SQL
Soy (Closure Template)
Stylus
Swift
TAP
Tcl
Textile
Template Toolkit 2
Twig
TypeScript
VB.Net
Velocity
Verilog
VHDL
vim
Visual Basic
WebAssembly
Wiki markup
Xeora
Xojo (REALbasic)
XQuery
YAML
HTML
Paste Expiration :
[Optional]
Never
Self Destroy
10 Minutes
1 Hour
1 Day
1 Week
2 Weeks
1 Month
6 Months
1 Year
Paste Status :
[Optional]
Public
Unlisted
Private (members only)
Password :
[Optional]
Description:
[Optional]
Tags:
[Optional]
Encrypt Paste
(
?
)
Create New Paste
You are currently not logged in, this means you can not edit or delete anything you paste.
Sign Up
or
Login
Site Languages
×
English
Tiếng Việt
भारत