Logistic regression was not significant in vessel distribution for sex (OR 0.6, 95% CI 0.28-1.15; p = 0.11). Inter-observer agreement in detecting LCA was substantial (kappa 0.71, 95% CI 0.59-0.83) and excellent for side/length distribution (kappa 0.94, 95% CI 0.82-1.0; ICC 0.96, 95% CI 0.93-0.98). The LCA is uncommon and most often unilateral and extends the third rib. Radiologists should be aware of this vessel and its potential role in angina after CABG, particularly when large. • LCA is an uncommon normal variant that is reported to cause angina pectoris after CABG. • CT angiography can reliably detect the LCA. It is most often unilateral and spans two intercostal spaces. • LCA is an uncommon normal variant that is reported to cause angina pectoris after CABG. • CT angiography can reliably detect the LCA. It is most often unilateral and spans two intercostal spaces. To illuminate the prognostic value of ADC (apparent diffusion coefficient), an important quantitative parameter of diffusion-weighted MRI, for multiple myeloma (MM). A prospective single-center study which enrolled 114 consecutive newly diagnosed MM patients with baseline whole-body diffusion-weighted MRI (WB DW-MRI) results was conducted. Baseline clinical and MRI parameters were analyzed with univariate and multivariate approaches to identify independent risk factors for progression-free survival (PFS) and overall survival (OS). Five different DW-MRI patterns were seen, and the mean ADC value of the representative background bone marrow was 0.4662 ± 0.1939 × 10 mm /s. After a mean follow-up of 50.2 months (range, 15.7-75.8 months), twenty-four patients died and seven were lost to follow-up. The mean ADC value of the representative background bone marrow was showed to be an independent risk factor for both PFS (HR 4.664; 95% confidence interval (CI) 1.138-19.121; p = 0.032) and OS (HR 14.130; 95% CI marrow (L3-S1 and iliac bone) was an independent risk factor for both PFS and OS. • Whole-body diffusion-weighted MRI (WB DW-MRI) might be helpful to improve the current risk stratification systems for newly diagnosed multiple myeloma (MM). • Morphological parameters as MRI pattern and focal lesion-associated parameters have been reported to be related to survival. https://www.selleckchem.com/products/lenalidomide-s1029.html However, important functional parameters such as apparent diffusion coefficient (ADC) values were not incorporated into the current risk stratification model. • This study is one of the first endeavors to delineate the correlation of baseline ADC values and survival in MM patients. It is revealed that the mean ADC value of the representative background bone marrow (L3-S1 and iliac bone) was an independent risk factor for both PFS and OS. To evaluate the diagnostic accuracy of venous-phase dual-energy computed tomography (VP-DECT) in the identification of PE compared with standard CT pulmonary angiography (CTPA). This prospective IRB-approved study included 61 consecutive oncology patients (35 females, 26 males, mean age 66.91 years) examined by CTPA and VP-DECT. DECT data were post-processed on a SyngoVia workstation to obtain monoenergetic images (MEI+). The diagnosis of PE was based on the presence of any vascular perfusion defects. DECT images were evaluated independently by two radiologists (8 and 16 years of experience). A consensus reading of CTPA images (two senior radiologists, 18 and 24 years of experience) represented the reference for diagnosis. The diagnostic accuracy values of VP-DECT on a per-patient and per-lobe basis were assessed. Interobserver agreement was calculated using k-statistics. A value of p < 0.05 was considered statistically significant. Thirty of 61 patients (49.18%) were diagnosed with PE by CTPA, with ous DECT were 73.33% and 67.74% as concerns the patients' analysis and 71.92% and 75.72% as regards the lobes' analysis, respectively. • With regard to the patients' analysis, venous-phase DECT sensitivity and specificity in diagnosing pulmonary embolism were 90% and 100%, respectively, for both readers. • With regard to the lobes' analysis, the sensitivity ranged from 100 to 50%, for reader 1, and from 100 to 69.23%, for reader 2, respectively. • The sensitivity and specificity of lung perfusion maps obtained from venous DECT were 73.33% and 67.74% as concerns the patients' analysis and 71.92% and 75.72% as regards the lobes' analysis, respectively. To prospectively evaluate a 3D-multiecho-Dixon sequence with inline calculation of proton density fat fraction (PDFF) and R2* (qDixon), and an improved version of it (qDixon-WIP), for the MR-quantification of hepatic iron in a clinical setting. Patients with increased serum ferritin underwent 1.5-T MRI of the liver for the evaluation of hepatic iron overload. The imaging protocol for R2* quantification included as follows (1) a validated, 2D multigradient-echo sequence (initial TE 0.99 ms, R2*-ME-GRE), (2) a 3D-multiecho-Dixon sequence with inline calculation of PDFF and R2* (initial TE 2.38 ms, R2*-qDixon), and optionally (3) a prototype (works-in-progress, WIP) version of the latter (initial TE 1.04 ms, R2*-qDixon-WIP) with improved water/fat separation and noise-corrected parameter fitting. For all sequences, three manually co-registered regions of interest (ROIs) were placed in the liver. R2* values were compared and linear regression analysis and Bland-Altman plots calculated. Forty-six out of 415 Dixon sequence eliminates minor drawbacks. • The 3D-multiecho-Dixon sequence for 1.5 T is a reliable tool to quantify hepatic iron. • Results of the 3D-multiecho-Dixon sequence are comparable with established relaxometry methods. • An improved version of the 3D-multiecho-Dixon sequence eliminates minor drawbacks.Wearable monitoring devices are an innovative way to measure heart rate (HR) and heart rate variability (HRV), however, there is still debate about the validity of these wearables. This study aimed to validate the accuracy and predictive value of the Empatica E4 wristband against the VU University Ambulatory Monitoring System (VU-AMS) in a clinical population of traumatized adolescents in residential care. A sample of 345 recordings of both the Empatica E4 wristband and the VU-AMS was derived from a feasibility study that included fifteen participants. They wore both devices during two experimental testing and twelve intervention sessions. We used correlations, cross-correlations, Mann-Whitney tests, difference factors, Bland-Altman plots, and Limits of Agreement to evaluate differences in outcomes between devices. Significant correlations were found between Empatica E4 and VU-AMS recordings for HR, SDNN, RMSSD, and HF recordings. There was a significant difference between the devices for all parameters but HR, although effect sizes were small for SDNN, LF, and HF.